Solar Inverter Sizing Calculator
Inverter Sizing Calculator
Size the inverter from the DC array and your DC:AC ratio, with its AC output current. Adjust any input and the result updates live.
Inputs
Updates liveResults
LiveOptimal
Recommended Inverter
kVA
AC Output Current
A at 230 V
Clipping Loss
needs yield simulation
Optimal
Ideal DC:AC ratio for maximum yield with minimal clipping losses.
Configuration
String Inverter — 4.3 kVA
“Inverter AC rating = DC kWp ÷ your chosen DC:AC ratio; AC current = kVA ÷ 230 V single-phase, or kVA ÷ (√3 × 415 V) three-phase. The grade bands (1.05–1.25 optimal, up to 1.35 acceptable) are this calculator's guide, not from a standard: the clipping loss depends on the site's irradiance and needs an hourly yield simulation. Grid-connected inverters must meet the CEA connectivity regulations.”
About the Inverter Sizing
Inverter sizing determines the right AC inverter rating for a given solar array, set by the DC-to-AC ratio (also called the inverter loading ratio, ILR). Correct sizing maximizes energy harvest while keeping clipping losses acceptable.
Last updated · How we build our calculators
Formula
Inverter AC rating (kVA) = DC array size (kWp) ÷ DC:AC ratio
- DC array size
- Total module rating (kWp)
- DC:AC ratio
- Your choice; this calculator grades 1.05–1.25 as optimal and up to 1.35 as acceptable (its own guide bands)
- AC current
- kVA ÷ 230 V single-phase, or kVA ÷ (√3 × 415 V) three-phase
How to calculate it
- 1Total the module DC capacity (kWp) of the array.
- 2Choose a DC:AC ratio; the clipping loss it causes depends on the site's irradiance and needs an hourly yield simulation to quantify.
- 3Divide DC capacity by the ratio for the inverter AC rating, and pick the nearest standard model.
- 4Check the strings with the String Sizing and Inverter Input Current calculators: voltage within the MPPT window and below the maximum on cold days, current within each MPPT's limit.
Worked example
A 5 kWp array at a 1.15 DC:AC ratio (the calculator's defaults) needs a 4.35 kVA inverter — 18.9 A on a 230 V single-phase supply — so a standard 4.6 or 5 kW unit. Slight over-sizing of the array relative to the inverter is intentional.
What you can calculate
- kVA recommendation
- DC:AC ratio
- AC output current
- Phase matching
Standards & references
Frequently asked questions
Can the solar array be larger than the inverter?
Yes — and it usually is. With a DC:AC ratio above 1, the array produces more energy in the mornings, evenings and cloudy hours, at the cost of some clipping around noon on clear days. How much clipping depends on the site's irradiance; a yield simulation quantifies it.
What happens if the inverter is undersized or oversized?
An undersized inverter (very high DC:AC ratio) clips more of the peak generation. An oversized one runs more of the time at part load and costs more for little extra energy. The balance depends on the site's irradiance and prices, so compare a few ratios in a yield simulation.
Ready to build your solar project?
Get free quotes from verified EPCs and installers across India.
You might also need
System Designer
Design custom solar system with component selection and layout optimization
OpenPanel Requirements
Calculate number of panels needed based on your energy consumption and roof space
OpenBattery Bank Sizing
LFP / NMC / Lead-Acid bank sizing with DoD, autonomy hours, temp derating, and S×P config
OpenSolar Plant Size
Size your plant in kWp from load (kWh/day) or available rooftop area
OpenString Sizing
Temperature-corrected Voc / Vmp string sizing with MPPT window and safety margin checks
OpenMPPT Window Check
Verify string voltage stays within inverter MPPT limits at Tmin and Tmax
Open